{"product_id":"first-choice-psmel2000-two-door-power-supply-exit-devices-12-24v-1-amp-r9dso3","title":"First Choice - PSMEL2000 - Two Door Power Supply \/ Exit Devices - 12\/24V - 1 AMP","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003eSmart Self-Diagnosing Power Supply \u003cstrong\u003ePSMEL200\u003c\/strong\u003e Operates a pair of doors with two low current exit devices simultaneously or independently control two single door leaf's.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eShall operate up to two (2) 24VDC panic hardware devices simultaneously\u003c\/li\u003e\n\u003cli\u003eEach lock output shall have an adjustable relock delay timer\u003c\/li\u003e\n\u003cli\u003eIt shall control a pair of doors simultaneously or independently two doors\u003c\/li\u003e\n\u003cli\u003eRelay for each output to trigger external relays, ADA push plate switches, etc.\u003c\/li\u003e\n\u003cli\u003eDelayed follower relays shall control automatic door operators for doors that are always locked or for doors that are unlocked during the business day\u003c\/li\u003e\n\u003cli\u003eTwo un-switched auxiliary voltage outputs shall provide\/remove power to the lock outputs when activated\u003c\/li\u003e\n\u003cli\u003eA programmable FACP interface shall provide power\/remove power to the lock outputs when activated\u003c\/li\u003e\n\u003cli\u003eShall have LED status indicators monitor AC, FACP status \u0026amp; for lock output wiring supervision\u003c\/li\u003e\n\u003cli\u003eIntelligent logic shall provide protection against accidental shorting of lock outputs\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eSmart Visual Indicators\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e• Output 1 \u0026amp; 2 = Red (ON) input LEDs indicate panic device status is energized (rapid blink\/short or over current) (slow blink\/open circuit)\u003cbr\u003e• FAI = Green (ON) FACP Input Triggered (Alarm Condition)\u003cbr\u003e• Battery Trouble = Red (ON) Battery Normal (slow blink\/bad battery or no battery)\u003cbr\u003e• AC Trouble = Green (ON) AC normal (slow blink\/AC low or missing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eVisual Indicators\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e• Output 1 (On\/Over\/Open)\u003cbr\u003e• Output 2 (On\/Over\/Open)\u003cbr\u003e• FAI (On\/Off)\u003cbr\u003e• Battery (On\/Off)\u003cbr\u003e• AC Trouble (On\/Low or Missing)\u003cbr\u003e• AC Power (On\/Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eBattery Backup\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e• Built-in charger for sealed lead acid or gel type batteries\u003cbr\u003e• Automatic switch over to stand-by battery when AC fails\u003cbr\u003e• Maximum charge current .65 amps\u003cbr\u003e• 4AA batteries will make emergency stand-by at least 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eInput\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e\n\u003cspan data-mce-fragment=\"1\"\u003e• \u003c\/span\u003eInput 115VAC 60Hz, 2.5 amp or 230VAC, 50Hz, 1.5 amps\u003cbr\u003e• Two (2) N.O. Trigger Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eOutputs\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e• Two (2) 24 VDC individually controlled lock outputs rated @ 1 amp each. Load connected not to exceed 1 amp.\u003cbr\u003e• One (1) 24VDC @ .08 amps filtered regulated auxiliary output. (Not affected by FACP trigger)\u003cbr\u003e• One (1)12 VDC @ .05 amp filtered regulated auxiliary output. (Not affected by FACP trigger) Note: Total combined current for the 24VDC outputs may not exceed 1.75 amp.\u003cbr\u003e• Two (2) follower N.O. outputs for controlling ADA actuators\/ accessories\u003cbr\u003e• Two (2) momentary operator activation outputs\u003cbr\u003e• Trouble output relay for indicating low\/AC Voltage and battery trouble.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e13\" x 12.5\" x 3.5\" (H x W x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 29.4934%;\"\u003e\u003cspan\u003eCode \/ Agency Listings\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 67.7028%;\"\u003e• UL File for Access Control Systems Units (UL 294)\u003cbr\u003e• CUL Listed – CSA Standard C22.2 No. 205-M983, Signal Equipment's\u003cbr\u003e• CSFM – California State Fire Marshal Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e","brand":"First Choice","offers":[{"title":"Default Title","offer_id":52457665069276,"sku":"FCH-PSMEL2000","price":470.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0849\/0047\/9196\/files\/fmk3d3khspvi_7ed350e7-0b6a-45e7-ae47-fc975a449bbd.jpg?v=1788789239","url":"https:\/\/uhshardwares.com\/products\/first-choice-psmel2000-two-door-power-supply-exit-devices-12-24v-1-amp-r9dso3","provider":"UHS-hardware","version":"1.0","type":"link"}